DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Object Repair Procedures

Page10-550DTMR-PT [Dual Tone Multifrequency Port (TTR)]

10
System Technician-Demanded Tests:
Descriptions and Error Codes

Always investigate tests in the order presented in the table below when

inspecting errors in the system. By clearing error codes associated with the

Tone Detection Verification Test,

for example, you may also clear errors generated

from other tests in the testing sequence.

Tone Detection Verification Test (#42)

This test verifies the "touch-tone digits detection" capability of the DTMR port is

functioning properly.

1. D = Destructive; ND = Nondestructive
Order of Investigation Short Test
Sequence Long Test
Sequence D/ND1
Tone Detection Verification Test (#42) X X ND
Tone Detector Audit/Update Test (#43) X X ND
Table 10-183. TEST #42 Tone Detection Verification Test
Error
Code Test
Result Description/ Recommendation
none ABORT The system was not able to allocate all the resources needed for this test
or there was an Internal System Error.
1 ABORT The system could not allocate all the resources needed to test the DTMR
port.
1001 ABORT The system was unable to put the DTMR port in the appropriate mode to
test it.
1002 ABORT The system could not allocate time slots for the test connection. This could
happen when the system is heavily loaded. If the system is not heavily
loaded, then test the TDM Bus via the test tdm [a|b] command. Refer to
the TDM-BUS (TDM Bus) Maintenance documentation for details.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
Continued on next page