DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Object Repair Procedures

Page10-824MET-LINE (MET Line)

10
MET Line Ringer Update Test (#62)

In this update, a "ringer on" or a "ringer off" message is sent to the firmware to

start and stop the ringer on the set.

2000 ABORT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
FAIL The test failed due to an internal system error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
PASS Hybrid Line Station Audits passed.
1. Although this test always returns a PASS result, it may enter Error
Types 257 or 513 into the Error Log. To determine if there are any
problems that don’t show up in the test result, look for these error
types in the Error Log.
2. If these errors appear in the Error Log, or if user complaints still
exist, investigate by using other circuit pack tests, and by
examining the station, wiring, and connections.
0NO
BOARD The test could not relate the internal ID to the port (no board). This
could be due to incorrect translations, no board i s inser ted, an i ncorr ect
board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations a re correct . Use t he li st
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the
linkage between the internal ID and the port. If this is not the case,
check to ensure that there is a valid board inserted.
Table 10-276. TEST #61 MET Line Station Audits Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page