DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Object Repair Procedures

Page10-942PE-BCHL (PRI Endpoint Port)

10
Signaling Link State Check Test (#255)

As is noted in the general description for a PRI Endpoint Port, the operation of the

PRI Endpoint Port depends on the health of the UDS1 interface circuit pack and

of the TN765 Processor Interface Link. This test checks the status of those critical

elements.

PASS The port translation has been updated successfully. The current port
states kept in the UDS1 interface circuit pack and in the switch software
are consistent. If the port is busied out, the test does not run, but returns
PASS. To verify that the port is in-service:
1. Enter status pri-endpoint <extension> to verify that the port is
in-service. If the port is in-service, no further action is necessary. If the
port is out-of-service, go to Step 2.
2. Enter the release pri-endpoint <extension> command or the release
port <PCSSpp> command to put the port back into in-service.
3. Retry the test command.
Table 10-317. TEST #255 Signaling Link State Check Test
Error
Code Test
Result Description/Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1700 ABORT Rollabout video abort. The PRI terminal adapter associated with this PRI
endpoint extension is detached from the circuit pack. This is a normal abort
when the rollabout video feature is enabled. To complete the test on this port,
do one of the following:
1. Re-attach the disconnected PRI terminal adapter, or
2. Disable the rollabout video feature on this circuit pack by entering the
change ds1 PCSS command, and set the field "Alarm when PRI Endpoint
Detached?" to "y."
Continued on next page
Table 10-316. TEST #36 Audit and Update Test — Continued
Error
Code Test
Result Description/Recommendation
Continued on next page