DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Object Repair Procedures

Page10-1119SHDW-CIR (Common Shadow Circuit)

10
Error Log Entries and Test to Clear Values
System Technician-Demanded Tests:
Descriptions and Error Codes

Always investigate tests in the order they are presented in the table below. By

clearing error codes associated with the

Duplication Interface Circuit Pack Status Query Test,

for example, you may also clear errors generated from other tests in

the testing sequence.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Table 10-401. Common Shadow Circuit Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
010 Any Any Any test duplication 1C sh r 1
1 Common Shadow Cir c u i t
Loop Back Test (#283) MAJOR ON test duplication 1C r 3
257 Any Common Shadow Circuit
Time-Out Query Test (#285) MAJOR OFF test duplication 1C l r 3
513 1,2 Common Shadow Circuit
Address Decoder Test (#284) MAJOR ON test duplication 1C r 3
Order of Investigation Short Test
Sequence Long Test
Sequence D/ND1
Duplication Interface Circuit Pack Status Query Test
(#315) (a) XXND
Duplication Interface Circuit Pack Sanity Circuit Test
(#273) (a) XD
Duplication Interface Circuit Pack Sanity Maze Test
(#277) (a) XXND
Duplication Interface Circuit Pack SPE A Loop Back Test
(#275) (a) XXND
Duplication Interface Circuit Pack SPE B Loop Back Test
(#276) (a) XXND
Duplication Interface Circuit Pack Manager I Loop Back
Test (#274) (a) XXND
Continued on next page