DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids

Page8-147list testcalls

8
Examples
list testcalls detail
list testcalls detail print
list testcalls detail grp 78
list testcalls detail grp 78 result marg count 3 schedule
list testcalls detail grp 78 to-grp 80
list testcalls detail grp 78 to-grp 80 mem 1 print
list testcalls detail grp 78 to-grp 80 mem 1 not-result pass
list testcalls detail grp 78 to-grp 80 mem 1 count 2 schedule
list testcalls detail grp 78 to-grp 80 mem 1 to-mem 5
list testcalls detail grp 78 to-grp 80 mem 1 to-mem 5 count 3 print
list testcalls detail grp 78 to-grp 80 mem 1 to-mem 5 count 3 result pass
list testcalls detail mem 1 count 3 result pass
list testcalls detail to-grp 78 to-mem 4 count 3 result pass
list testcalls detail to-mem 3 result pass
list testcalls detail port 1c1504
list testcalls detail port 1c1504 count 5 schedule
list testcalls detail port 1c1504 count 5 not-result marg print
list testcalls summary
list testcalls summary grp 78
list testcalls summary grp 78 print
list testcalls summary grp 78 count 5
list testcalls summary grp 78 count 5 schedule
list testcalls summary grp 78 to-grp 80
1. Refer to the Report Scheduler an d System Printer feature specifi cation for more details.
to-mem member
number
Measurements for all trunk group members from 1 to the
specified "to-mem" trunk group member displayed. When used
with the
mem
option, this option is the en ding trunk group
member in a range of user-specified trunk group members.
port location
Measurements for a specific trunk circuit (port) displayed
result result identifier
This option is used to filter out all measurement results that do
not match the user-specified result, that is, only meas urement
results that match the user specified result are displayed.
Examples of results are pass, m arg, fail, etc.
not-result result
identifier
This option is used to filter out all measurement results that do
match the user-specified result, that is, only measurement
results that do not match the user spec ified result are displayed.
Examples of results are pass, m arg, fail, etc.
count count number
This option is used to spec ify (limit) the number of records
displayed.
print
Report sent to printer
schedule
Command is validated and th en a scheduling form displays to
schedule execution of th e command. The command is then
placed in the command queu e and is executed at the spe cified
time. The information displayed by the command is sent to the
system printer instead of the screen.1
Action/Object Qualifiers/Options Qualifier/Option Description