DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids

Page8-302status system

8
Output
The following example shows the output from the status system all-cabin ets
command.
Field descriptions
1. For PPN, and 1st and 2nd EPN s, one page of output displays.
2. The status displayed for a cabinet is always related to th at cabinet except in the case o f status for EPNs and
the SPE attributes. SPE att ributes always refer to PPN st atus regardless of which ca binet is being displayed.
Action/Object Qualifier Qualifier Description Permissions Defaults Feature
Interactions
status system

cabinet 1st-cabinet

: PPN

2nd-cabinet

: 1st EPN

3rd-cabinet

: 2nd EPN1

all-cabinets

: 3-pg. output - 1 for
each cabinet 2
Examples:
status system 1st-cabinet
status system 2nd-cabinet
status system 3rd-cabinet
status system all-cabinets
init
inads
craft
cust
rcust
bcms
browse
none none
SPE Switch Process Element (SPE) identifier: 1A or 1B
status system all-cabinets Page 1 of 3 SPE B
SYSTEM STATUS CABINET 1
SELECT SPE ALARMS TONE/ SERVICE SYSTEM SYSTEM
SPE MODE SWITCH MAJOR MINOR CLOCK STATE CLOCK TONE
1A busyout/not-refreshed auto n y 1A in standby standby
1B active auto n n 1B in active active
SERVICE CONTROL DEDICATED SERVICE BUS ALARMS BUS OPEN BUS
TDM STATE CHANNEL TONES PKT STATE MAJOR MINOR FAULTS LEADS
1A in y n 1 in n n 0 0
1B in n y
EMERGENCY SELECT SERVICE CABINET
TRANSFER SWITCH EXP-LINK STATE MODE TYPE
1A auto-off 01A01-02A01 out down SCC
1B auto-off 01B01-02B02 in active
01A02-03A01 in active
01B02-03B02 in standby