DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids

Page8-316test access-endpoint

8
test access-e ndpoint

This command performs hardware diagnostic tests on all port circuits that are

associated with the specified access endpoint extension.

1. If no alarms are registe red against the maintenan ce object then the test seq uence is run only once. The
long clear
option forces a clear of al l alarms if no errors are en countered during testing. Th e
short clear
option only clears
alarms pertinent to tests in th e short sequence.
2. Refer to the Report Schedu ler and System Printer feature sp ecification for more details.
Action/
Object Qualifier Qualifier Description Permissions Defaults Feature
Interactions
test
access-
endpoint
extension
short
long
repeat
number
clear
schedule
Access endpoint extension (# of digits
determined by dial-plan)
Option for a brief series of nondestructive
diagnostic tests.
Option for a longer, more comprehensive
test series (includes a destructive test)
How many times each test in the sequence
is repeated (1-100)
This option causes the tes t sequence (short
or long) to repeat until the alarm (if any) is
cleared or a single test in the sequence
fails.1
Command is validated and then a
scheduling form displays to schedule
execution of the command. Th e c omm an d is
then placed in the command queue and is
executed at the specified time. The
information displayed by th e command is
sent to the system printer instead of the
screen.2
Examples:
test access-endpoint 25012
test access-endpoint 45002 sh
test access-endpoint 45892 l
test access-endpoint 24389 sh r 4
test access-endpoint 3489 9 l r 6
test access-endpoint 3491 2 l r 5 schedule
test access-endpoint 9348 3 r 2
test access-endpoint 10022 c
test access-endpoint 92349 sche dul e
init
inads
craft
nms
Test
sequence
= short;
repeat =
1
none