DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Object Repair Procedures

Page10-70ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line)

10
Battery Feed Test (also called Port Diagnostic Test) (#35)

The battery feed chip provides power to the telephone eq uipment, signaling,

rotary dial pulsing, transmission, and balance. This test checks the signaling and

switchhook capabilities of the battery feed chip by term inating the port, applying

battery, and trying to detect a current.

Table 10-28. TEST #35 Battery Feed Test
Error
Code Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of five times.
1000 ABORT System resources required to run this test are not available. The port may
be busy with a valid call. Use the display port PCSSpp command to
determine the station extension. Use the status station command to
determine the service state of the port. If the service st at e indi cates t hat the
port is in use, then the port is unavailable for certain tests. (Refer to the
"Status Commands" section in Chapter 8, "Maintenance Commands and
Trouble-Clearing Aids", for a full description of all possible states.) You
must wait until the por t is idle before retes ting.
1. If the port status is idle, then retry the command at one-minute inte rvals
a maximum of five times.
1004 ABORT System resources required to run this test are not available. The port may
be busy with a valid call. Use the display port PCSSpp command to
determine the station extension. Use the status station command to
determine the service state of the port. If the service st at e indi cates t hat the
port is in use, then the port is unavailable for certain tests. (Refer to the
"Status Commands" section in Chapter 8, "Maintenance Commands and
Trouble-Clearing Aids", for a full description of all possible states.) You
must wait until the por t is idle before retes ting.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort and the port is not in use, escalate the
problem.
1005 ABORT The test was aborted due to a configuration problem. This code will result
under either of the following conditions:
1. This test may not be applicable, or it may be disruptive to terminal
equipment other than a voice terminal (for example, the modem pool
member or music on hold).
2. The circuit pack is one of the following:
TN742 vintages 13,14 and 15
TN769 vintages 3,4 and 5
Continued on next page