DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127 Issue 1
August 1997
Maintenance Object Repair Procedures

Page10-178BRI-SET, ASAI-ADJ, BRI-DAT

10
BRI-SET, ASAI-ADJ, BRI-DAT
!CAUTION:

A detailed flowchart for isolating and resolving Packet Bus faults is included

in Chapter 9, "Packet Bus Fault Isolation and Correction". This flowchart,

along with the other information presented in the chapter, can help in

resolving problems that involve more than a single station or circuit pack.

Whenever the repair procedures for this Maintenance Object refer to

Packet Bus and/or Packet Control maintenance, be sure to reference

Chapter 9, "Packet Bus Fault Isolation and Correction" in addition to the

relevant MO documentation.
1. Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier des ignation
(A, B, C, D, or E); SS is the address of the slot in the carrier where the circuit pack is located
(01, 02, ..., etc.); and pp is the 2-digit port number (for example, 01) . The alternate name field
contains the extension of the endpoint. This field is used to distinguish bet w een endpoints on
the same port.
2. The alarm level for ASAI and AT&T adjuncts may be administered using the set options
command. The alarm level can be set independently for Off-Board and On-Board alarms to
WARNING, MINOR, or MAJOR for all ASAI and AT&T adjuncts in the system.
3. Alarming for an ASAI and AT&T adjuncts is disabled if the adjunct asks the switch to suspend
maintenance. When this occurs, an error and a WARNING alarm are logged against the
endpoint. Busying out and releasing the ASAI station or ADJLK station will clear the alarm.
MO Name (in
Alarm Log) Alarm Level Initial Command to Run1Full Name of MO
BRI-SET WARNING2test station extension l,
test data-module extension ISDN-BRI Set
ASAI-ADJ MAJOR2test station extension ASAI-Adjunct
ASAI-ADJ MAJOR2test data-module extension ASAI-Adjunct
ASAI-ADJ WARNING3test data-module extension ASAI-Adjunct
ATT-ADJ MAJOR2test station extension AT&T-Adjunct
ATT-ADJ MAJOR2test station extension AT&T-Adjunct
ATT-ADJ WARNING3test station extension AT&T-Adjunct
LGATE-AJ MAJOR2test station extension Ethernet ASAI-Adjunct
LGATE-AJ MAJOR2test station extension Ethernet ASAI-Adjunct
LGATE-AJ WARNING3test station extension Ethernet ASAI-Adjunct
ATTE-AJ MAJOR2test station extension Ethernet AT&T-Adjunct
ATTE-AJ MAJOR2test station extension Ethernet AT&T-Adjunct
ATTE-AJ WARNING3test station extension Ethernet AT&T-Adjunct
BRI-DAT test data-module