Madrigal Imaging MP-9 Environment Maximum Operating Range, Storage, Heat Dissipation, Mounting

Models: MP-8, MP-9 MP-9

1 138
Download 138 pages 24.6 Kb
Page 108
Image 108

SPECIFICATIONS

Environment Maximum Operating Range

Temperature: 0 to 35°C

Humidity: 0 to 90% non-condensing

Altitude: 0 to 10,000 ft. (0-3,000m.)

Storage

Temperature: -30°C to 65°C

Heat Dissipation

2450 BTU/Hr (approximate)

Mounting

Can be ceiling mounted on its optional ceiling mount or placed on a

 

 

castered cart for portable applications

Weight

176 lbs / 80 kg

 

 

229 lbs / 104 kg (shipping weight)

Accessories

Convertible multi-use, backlit full function keypad

Included

 

Line Cord and User's Manual

 

 

Tool Kit

 

 

ACON® II which automates the convergence process, performing com-

 

 

 

plete convergence in less than 3 minutes

Options

Various interfaces: RGB Input Module, RGB Loop Thru Module,

& Accessories

 

 

Composite/S-Video Module, HDTV Input Module and PC Analog

 

 

 

Input Module.

 

 

Signal Switcher

 

 

Adapter cables

 

 

Ceiling mount and rear screen equipment

 

 

RETRO III large screen projection

 

 

Castered cart

 

 

Librarian software, Encyclopedia software

 

 

Contact your dealer or Madrigal for more information about the above

 

 

products and accessories. Also refer to Appendix H, Interfaces.

Regulatory

FCC Class A, DHHS and HWC requirements, EN55022 Class B

Approvals

 

CSA/UL/EN 60 950

EU Directives 73/23/EEC, 89/336/EEC (CE marked)

Warranty One year parts and labor for tube (see inside back cover)

Three years parts and labor for everything else (see inside back cover)

5.4