SPECIFICATIONS

Notes: 1. Blanking can be increased with left and right blanking controls

2.Retrace fixed as Short in ranges 45–60 kHz and 100–152 kHz despite user setting

3.Defl. retrace time must be less than the max. blanking duration

4.Horizontal blanking duration of the source must be more than the max. blanking duration of the projector to avoid cutting off the left or right edge of the source image.

5.Max. Blanking duration of the projector must be compatible with all known sources (at the specific source frequency).

6.Max. Blanking duration of the projector restricted to 1.5µs for operation in the range 120 kHz–152kHz.

High Voltage

34.9 KV regulated to better than ±1%

Power

90 VAC to 264 VAC universal input

Requirements

Line Frequency: 50 to 60 Hz nominal

 

Power: 650 watts maximum

 

Power factor corrected

Inputs

Built-in RGBHV interface. Optional interface modules install in

 

 

interface slot

 

Built-in RS-232 for computer control, with loop-thru for connection

 

 

of multiple projectors

 

HDTV compatible with optional interface module

Optional Source

The Signal Switcher allows use of nine additional input modules. Up

Expansion

 

to nine switchers can be connected

 

Maximum Number of Inputs: 78

Control Features Multi-language software (user selectable)

Menu driven interface with on-screen help

Built-in set up tutorials

Auto power up after power interruption

Six built-in test patterns

Internal frequency generator

Programmable events and real time clock

Servicing Modular design for ease of servicing

Most service adjustments are made using the keypad

5.3