2.11ACON Setup

CON

 

INSTALLATION & SETUP

Step 2

 

Press

twice to display the Current Input Parameters status page. Check

to see if ASR is off for the current input. If it is on, press EXIT then press

UTIL 1

4 to turn ASR off for the input.

Step 3

At the switcher, switch in one of the source devices. Select an unused Recall memory as the current setup memory. For example, to make Recall memory 01 the current setup memory, press RECALL 0 1 . Make display adjustments as required. The display settings for the selected device will be stored in the Recall memory. Repeat this step for the remaining devices.

Step 4

Press UTIL 1 5 to display the Clear Setup dialog box. Move the cursor to “Do It” then press ENTER to clear the display settings and frequency settings of the input. By doing this, Input memory 01 will not be used during an ASR search.

Step 5

 

 

 

Press

UTIL

1

3

to lock Input memory 01 to prevent display or frequency

changes to the Input memory.

Step 6

 

 

 

Press

UTIL

1

4

to turn ASR on for the input. The projector’s display settings

will automatically adjust to match the source selected by the switcher.

This section provides setup and usage guidelines for systems which include the ACON automatic convergence feature.

There are a few simple rules and operation fundamentals which should be understood and considered when installing a projector which includes the ACON automatic convergence feature. ACON operates on the principle of monitoring projected screen images via its Locator Assembly, analyzing this data, then adjusting the vertical and horizontal positions of the red and blue colors until optimum convergence with the green is achieved. This process requires that the view of the display screen by the Locator Assembly be totally unobstructed. ACON’s performance can be adversely affected if the projector’s optical and system functions are not properly set. Ensure the pro- jector is focused and all user adjustments have been made prior to operating ACON.

Figure 2-29 illustrates two common projection system configurations. ACON responds differently for each configuration. The projector configuration is determined by ACON during the Learn Screen process. Always perform a Learn Screen for a new or changed installation. For more information on Learn Screen, refer to section 3.6, Convergence Registration.

2.35

Page 41
Image 41
Madrigal Imaging MP-8, MP-9 manual Acon Setup