13.1.3Capacity confirmation of the project data downloading location
When download the project data, confirm the capacity of the user area in the drive to which transferred, the transferred project data size, the transfer size and buffering area size of the optional function OS in advance to judge whether to carry out the download.
The capacities can be confirmed by GT Designer3. For details, refer to the following. GT Designer3 Version1 Screen Design Manual (Fundamentals)
13.1.4Display file
The display screen and storage destination for each type of data are shown below.
The file name and contents of each data can be displayed with property display of the utility
| Item | Display screen | Storage destination (Drive name/folder name) | |
BootOS |
|
| A drive/C drive/E drive | |
|
| : \G1BOOT\*2 | ||
|
|
| ||
| Standard monitor OS system screen data |
|
| |
|
|
|
| |
| Standard monitor OS system screen |
|
| |
| management information file |
|
| |
|
|
|
| |
| Standard monitor OS (monitor function) |
|
| |
|
|
|
| |
Standard monitor OS | 6 |
|
| |
|
|
| ||
OS information screen | A drive/C drive/E drive*3 | |||
| ||||
|
| |||
|
| : \G1SYS\*2 | ||
|
|
| ||
| TrueType numerical font |
| ||
|
|
| ||
|
|
|
| |
|
|
| ||
|
|
|
| |
|
|
| ||
|
|
|
| |
Extended function OS |
|
|
| |
|
|
|
| |
Option OS |
|
|
| |
|
|
|
| |
Communication driver |
|
|
| |
|
|
|
| |
Project data*1 |
|
|
| |
|
|
| ||
|
|
| A drive/C drive/E drive*3 | |
| Comment data | Project information | ||
|
| screen | :\PROJECT1\*2*4 | |
| ||||
|
|
| ||
|
|
|
| |
| TrueType (Mincho/Gothic) |
|
| |
|
|
|
| |
| Advanced alarm log file CSV file*5 |
|
| |
| Advanced alarm log file TXT file*5 | Alarm information screen |
| |
| Advanced alarm log file binary file*5 |
| ||
|
|
| ||
| Alarm log file CSV file*5 |
|
| |
| Hard copy file BMP file*5 | Hard copy information | A drive/D drive/E drive *6 | |
| Hard copy file JPG file*5 | screen | ||
Resource data | : \ | |||
Advanced recipe file CSV file*5 |
| With GT Designer3, any folder name or file name can | ||
|
| |||
|
| Advanced recipe | be specified.*2 | |
| Advanced recipe file TXT file*5 | |||
| information screen |
| ||
| Advanced recipe file binary file*5 |
|
| |
| Logging file CSV file*5 | Logging information |
| |
| Logging file TXT file*5 |
| ||
| screen |
| ||
| Logging file binary file*5 |
|
|
*1 The
*2 Each folder is created automatically when a file is installed, downloaded, or uploaded.
*3 The USB memory cannot be activated directly from the E drive. It can be used only for data storage.
*4 The folder names and file names can be set at [System Settings] in [System Environment] of GT Designer3.
GT Designer3 Version1 Screen Design Manual (Fundamentals)
*5 A serial number is automatically added to file names.
*6 Each function does not provide direct storage to the E drive.
13 - 4 | 13. FILE DISPLAY AND COPY (PROGRAM/DATA CONTROL) |
| 13.1 Data Storage Location |