17.1 Daily Inspection

Daily inspection items

No.

 

Inspection Item

Inspection Method

Criterion

Action

1

Installation status of GOT

Check for loose

Securely mounted

Retighten screws within the specified torque

mounting screws.

range.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loose terminal screws

Retighten screws with

Not loose

Retighten terminal screws.

 

 

 

screwdriver.

 

 

 

 

 

 

2

Connection

 

 

 

 

 

 

Proximate solderless

 

 

 

status

 

Visual check

Proper intervals

Correct.

 

 

terminals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loose connectors

Visual check

Not loose

Retighten connector fixing screws.

 

 

 

 

 

 

 

 

Usage

 

Dirt on protection sheet

Visual check

Not outstanding

Replace with new one.

3

 

 

 

 

 

status

 

Foreign material

Visual check

No foreign matter sticking

Remove, clean.

 

 

 

 

 

attachment

 

 

 

 

 

 

 

 

 

 

 

 

 

For the model names of the protection sheet or the replacement procedure, refer to the following.

8.4 Protective Sheet

17.2 Periodic Inspection

Yearly or half-yearly inspection items

The following inspection should also be performed when equipment has been moved or modified or the wiring changed.

No.

Inspection Item

 

 

Inspection Method

Criterion

Action

 

 

Ambient

 

 

 

Display section

0 to 50

 

 

 

 

 

 

 

 

 

 

Surrounding

temperature

Make measurement with thermometer or

Other portions

0 to 55

For use in control panel, temperature

 

 

1

 

hygrometer.

 

 

inside control panel is ambient

environment

Ambient

10 to 90%RH

 

 

Measure corrosive gas.

 

temperature.

 

 

humidity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Atmosphere

 

 

 

No corrosive gas

 

 

 

 

 

 

 

 

 

 

2

Power supply voltage check

24VDC Measure voltage across

20.4 to 26.4VDC

 

Change supply power.

terminals.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Looseness

Move module.

Should be mounted firmly.

Retighten screws.

3

Mounting

 

 

 

 

 

 

 

Foreign

 

 

 

 

 

 

status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

material

Visual check

No foreign matter sticking

Remove, clean.

 

 

attachment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loose

 

 

 

 

 

 

 

 

terminal

Retighten screws with screwdriver.

Not loose

 

Retighten terminal screws.

 

 

screws

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Connection

Proximate

 

 

 

 

 

 

status

solderless

Visual check

Proper intervals

 

Correct.

 

 

 

 

terminals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loose

Visual check

Not loose

 

Retighten connector fixing screws.

 

 

connectors

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check GOT internal battery voltage

 

 

Replace with new battery when the

 

 

 

status in [Time Setting & Display] of the

 

 

5

Battery

 

Utility.

 

No alarm displayed

current battery has reached the

 

 

 

 

specified life span, even if battery

 

 

 

(

 

12.1.1 Time setting and display

 

 

 

 

 

 

 

 

voltage is not displayed.

 

 

 

functions)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17 - 2

17. MAINTENANCE AND INSPECTION

 

17.1 Daily Inspection