5.2.1Requirements to Meet EMC Directive
EMC Directives are those which require "any strong electromagnetic force is not output to the external.:Emission (electromagnetic interference)" and "It is not influenced by the electromagnetic wave from the external.: Immunity (electromagnetic sensitivity)".
Items EMC directive thru Grounding summarize the precautions to use GOT and configure the mechanical unit in order to match the EMC directives.
Though the data described herein are produced with our best on the basis of the requirement items and standards of the restrictions gathered by Mitsubishi, they do not completely guaranteed that all mechanical unit manufactured according to the data do not always match the above directives. The manufacturer itself which manufactures the mechanical unit must finally judge the method and others to match the EMC directives.
EMC directive
The standards of the EMC Directive are shown below.
Applied standard | Test standard | Test details | Standard value | ||
|
|
|
| ||
| EN55011 | Electromagnetic emissions from the | 30dB V/m (30m in measurement range)*2, *3 | ||
| Radiated noise*1 | product are measured. |
| ||
|
|
| 37dB V/m(30m in measurement range)*2, *3 | ||
| Immunity test in which static electricity is | 4kV Contact discharge |
| ||
| Electrostatic immunity*1 | applied to the cabinet of the equipment. | 8kV Aerial discharge |
| |
|
|
| |||
| Immunity test in which field is irradiated |
| |||
| Radiated field AM |
| |||
| to the product. |
| |||
| modulation*1 |
| |||
|
| 80%AM modulation@1kHz |
| ||
|
|
|
| ||
|
|
|
|
| |
| Immunity test in which burst noise is | Power line:2kV |
| ||
Digital I/O(24V or higher): 1kV | |||||
: 2007 | applied to the power line and signal | ||||
Fast transient burst noise*1 | (Digital I/O(24V or less))> 250V | ||||
|
| lines. | (Analog I/O, signal lines)> 250V | ||
|
|
| |||
|
|
|
| ||
| Immunity test in which lightening surge | Power line (between line and ground): 0.5kV | |||
| Power line (between lines): | 0.5kV | |||
| Surge immunity*1 | is applied to the product. | |||
| Data communication port: | 1kV | |||
|
|
| |||
|
|
|
|
| |
| Immunity test in which a noise inducted | Power line: 10V |
| ||
| Conducted RF immunity*1 | on the power and signal lines is applied. | Data communication port: 10V | ||
| Test for checking normal operations |
|
| ||
| under the circumstance exposed to the |
|
| ||
| Power supply frequency | 30 A/m |
| ||
| ferromagnetic field noise of the power |
| |||
| magnetic field immunity |
|
| ||
| supply frequency (50/60Hz). |
|
| ||
|
|
|
| ||
|
|
|
|
|
*1 The GOT is an open type device (device installed to another device) and must be installed in a conductive control panel.
The above test items are conducted in the condition where the GOT is installed on the conductive control panel and combined with the Mitsubishi PLC.
*2 QP:
*3 The above test items are conducted in the following conditions.