6.5 Installation Procedure
The GOT is designed to be embedded into a panel. Mount the GOT by following the procedure below. For the panel cutting dimension, refer to "6.2 Panel Cutting Dimension".
Also, be sure that the thickness of the mounting panel face is 2 to 4mm.
Packing
Magnified
1.
Installing the packing
Install packing to the packing installation groove on the back panel of the GOT.
While referring to the cross sectional view of the packing shown left, push the thinner side into the packing groove.
(Left drawing is the example of lateral format.)
illustration
Packing
Packing installation groove
Packing cross sectional view
Inserting direction
2.
Inserting into the panel face
Insert the GOT from the front side of the panel.
Mounting hole
Enlarged view
Mounting bracket
Mounting screw
3.
4.
Fixing the GOT
Engage the hook of the mounting fixture (accessory) to the unit fixing hole of the GOT and fix them by tightening the mounting screws in the torque range of 0.3 to 0.5N·m.
A protection film is attached on the display section of GOT prior to shipment.
Remove the film when the installation is completed.
6 - 4 | 6. INSTALLATION |