6.5 Installation Procedure

The GOT is designed to be embedded into a panel. Mount the GOT by following the procedure below. For the panel cutting dimension, refer to "6.2 Panel Cutting Dimension".

Also, be sure that the thickness of the mounting panel face is 2 to 4mm.

Packing

Magnified

1.

Installing the packing

Install packing to the packing installation groove on the back panel of the GOT.

While referring to the cross sectional view of the packing shown left, push the thinner side into the packing groove.

(Left drawing is the example of lateral format.)

illustration

Packing

Packing installation groove

Packing cross sectional view

Inserting direction

2.

Inserting into the panel face

Insert the GOT from the front side of the panel.

Mounting hole

Enlarged view

Mounting bracket

Mounting screw

3.

4.

Fixing the GOT

Engage the hook of the mounting fixture (accessory) to the unit fixing hole of the GOT and fix them by tightening the mounting screws in the torque range of 0.3 to 0.5N·m.

A protection film is attached on the display section of GOT prior to shipment.

Remove the film when the installation is completed.