Troubleshooting Network Boot Problems

Use the set command to correct settings, if necessary. For example, if the router has a token ring port and the wfDrivers.wfTMS380Load.0 setting is not 2147483648, enter the following command to correct it:

set wfDrivers.wfTMS380Load.0 2147483648;commit

If the router is netbooting with a synchronous interface, enter the following command to display information about the interface, where connector is the interface connector number:

get wfSyncEntry.*.1.<connector>

Ensure that external clocking is set.

If the router is netbooting with an Ethernet interface, enter the following command to display information about the interface, where connector is the interface connector number:

get wfCSMACDEntry.*.1.<connector>

If the router is netbooting with a token ring interface, enter the following command to display information about the interface, where connector is the interface connector number:

get wfTokenRingEntry.*.1.<connector>