391x Series AT Commands

AT

 

Description

DCP LCD

 

Command

Command

 

 

 

Sequence

 

 

 

 

 

 

&Fn

Select Factory Default Configuration Options. Loads factory configuration

Configure/

 

options into Active (Operating) area.

Factory

 

&F0

Async Dial

 

 

&F1

Sync Dial

 

 

&F2

Sync Leased: Answer

 

 

&F3

UNIX Dial

 

 

&F4

Sync Leased: Originate

 

 

&F5

Async Leased: Answer

 

 

&F6

Async Leased: Originate

 

 

&F7

TMp: Control

 

 

&F8

TMp: Trib

 

 

Only the &F0 and &F3 commands will leave you in AT Command mode.

 

 

The other commands will take you out of AT command control and place

 

 

the modem into Dumb mode. The only way to return to AT command

 

 

control is via the diagnostic control panel (DCP).

 

 

 

 

&Gn

V.22bis Guard Tone.

Configure\Edit\

 

&G0

Disable.

Dial Line

 

 

 

&G1

550 Hz.

 

 

&G2

1800 Hz.

 

 

NOTE: The V.22bis Guard Tone cannot be disabled in some countries.

 

 

 

 

 

 

&In

Dial Transmit Level.

Configure\Edit\

 

The AT command is &In, where n is

Dial Line

 

 

 

0 for ±1 dBm

 

 

1 for ±1 dBm

 

 

 

 

 

 

 

 

 

 

 

32 for ±32 dBm

 

 

NOTE: In North America the range of allowable values is ±10 dBm to

 

 

 

±32 dBm. This command is disabled in some countries (it

 

 

 

answers OK but does not change the level).

 

 

 

 

&Ln

Leased Mode.

Configure\Edit\

 

&L0

Disables leased-line operation.

Leased Line

 

 

 

&L1

2-wire originate leased-line operation.

 

 

&L2

4-wire originate leased-line operation.

 

 

&L3

2-wire answer leased-line operation.

 

 

&L4

4-wire answer leased-line operation.

 

 

The &L command will cause the modem to reset before entering or

 

 

exiting Leased-Line mode. Therefore, it must be entered as the last

 

 

command in an initialization string.

 

 

 

 

 

5-10