AT Command Set and S-Registers

Table 5-4

(11 of 13)

391x Series S-Registers

S-Register

 

Description

DCP LCD

 

Command

 

 

 

Sequence

 

 

 

S89

V.42 Automatic Request for Retransmission (ARQ) Window Size

 

 

Increase. Register allows the ARQ window size to be set to a value

 

 

from six frames to fifteen frames.

 

 

For best performance, this register should remain at its default setting

 

 

of six frames (ATS89 = 0). The only reason to change it is for satellite

 

 

delays.

 

 

Register has the following values:

 

 

0

= six frames

 

 

1

= seven frames

 

 

2

= eight frames

 

 

3

= nine frames

 

 

4

= ten frames

 

 

5

= eleven frames

 

 

6

= twelve frames

 

 

7

= thirteen frames

 

 

8

= fourteen frames

 

 

9

= fifteen frames

 

 

The factory setting is 0 (six frames).

 

 

This command only applies when the modem connects using V.42bis

 

 

data compression or V.42 error control. If the modem is configured for

 

 

Direct mode, MNP mode, Buffer mode, or Synchronous operation, this

 

 

command is invalid.

 

 

This command does not have a front panel equivalent.

 

 

 

 

S90

DTE Rate = VF. Register allows the DTE's data rate to be equal to the

Configure\Edit\

 

VF (telephone line) data rate. If Enabled, the data rate between the

DTE Interface

 

DTE and modem is the same as the modem's VF data rate. As a

 

 

result, when the modem is in Data mode, the speed of the data

 

 

passed between the modem and DTE occurs at the VF data rate.

 

 

Register has the following values:

 

 

0

= Disable

 

 

1

= Enable

 

 

The factory setting is Disable.

 

 

 

 

S91

Cellular Enhancement. Register allows the modem to use

Configure\Edit\

 

non-standard techniques to enhance V.42 operation for cellular

V42/MNP/Buffer

 

applications. It is still compatible, however, with modems which do not

 

 

have the cellular enhancement implemented or enabled.

 

 

Register has the following values:

 

 

0

= Disable

 

 

1

= Enable

 

 

The factory setting is Disable.

 

 

 

 

 