COMSPHERE 3900 Series Modems

 

Table B-5

 

(1 of 2)

 

Modem Ð VF Connection

 

 

Symptom

Action

 

 

The modem does not receive a

Attach a telephone directly to the telephone line to verify that a dial

dial tone.

tone exists.

 

Make sure the VF line is connected to the modem's rear jack labeled

 

DIAL.

 

 

The modem does not go off-hook

Verify that the Auto Answer Ring Count configuration option is set to a

and answer an incoming call.

value other than 0 (disable). Refer to Line Dialer in Chapter 4.

 

Verify that the DTE is providing DTR to the modem.

 

If the DTE does not provide DTR to the modem, verify that the

 

modem's DTR Action configuration option is set for Ignore. Refer to

 

DTE Interface in Chapter 4.

 

Verify that all cables are attached to the correct connectors on the rear

 

of the modem.

 

 

The modem goes off-hook,

Perform a Local Analog Loopback test and verify that data entered at

answers, but does not connect.

the DTE is echoed back to the DTE.

 

Verify that the originating modem is compatible with your receiving

 

modem.

 

Verify that the originating modem recognizes your modem's answer

 

tone.

 

Verify that the originating modem supports your modem's modulation

 

schemes. The 391x Series modem recognizes CCITT V.32bis, V.32,

 

V.22bis, V.22, V.21, Bell 212A, and Bell 103J. The 391x Series modem

 

does not support other vendors' proprietary modulation schemes.

 

Force your modem to operate at the same modulation scheme as the

 

originating modem to see if they connect.

 

 

The Originate Mode does not

Verify that the modem's DTE Dialer Type configuration option is set to

function properly.

the correct setting: either AT, DTR Dialing, V.25bis Async, V.25bis

 

Bisync, or V.25bis HDLC. Refer to DTE Dialer in Chapter 4.

 

 

The modem does not go off-hook

If using AT Dialing, refer to the Table B-2, ModemÐDTE Connection.

and begin dialing.

If using DTR Dialing, verify the telephone number stored in directory

 

 

location 1, and verify that the DTE is raising DTR from Off to ON to

 

initiate a dial.

 

If using V.25bis Async, verify that the correct character format is set to

 

7 data bits with even parity and 1 stop bit, and the carriage return and

 

line feed are used as command terminators.

 

If using V.25bis Bisync, verify that the correct character format uses

 

two synchronous control characters and a start-of-text control

 

character before the text block, and an end-of-text control character

 

after the text block.

 

If using V.25bis HDLC, verify that the character format uses flag,

 

address, and control characters before the text block and a frame

 

sequence check and flag after the text block.

 

 

B-4

November 1996

3910-A2-GN32-30

Page 189
Image 189
Paradyne 3910 operation manual Modem Ð VF Connection, Dial