DCP Configuration

Leased Line

The Leased Line configuration options only appear when the Sync Leased factory preset template is selected. They are used to configure the modem for operation over leased lines.

Table 4-5 shows each Leased Line configuration option as it appears on the LCD, with the Sync Leased factory default setting (the default value if the modem is just being installed) shown following the colon ( : ) on the first line and with all available selections listed on the second line. Following this is a description of the configuration option. Factory default settings are listed in Appendix F.

Table 4-5

(1 of 6)

Leased Line Configuration Options

Leased Mode: 4WLL-Ans

Nxt 4WLL-Ans 4WLL-Orig 2WLL-Orig 2WLL-Ans

Leased Mode. Sets the modem for either 2-wire or 4-wire operation in Answer mode (receiving a call) or 2-wire or 4-wire operation in Originate (initiating a call) mode.

NOTE: For proper operation of V.32 modulations over leased lines, one modem must be set to Originate mode and the other set to Answer mode.

For Sync Leased Answer Mode, Async Leased Answer Mode and Trellis Multipoint Tributary Mode, 4-wire Answer is the factory default.

For Sync Leased Originate Mode, Async Leased Originate Mode and Trellis Multipoint Control Mode, 4-wire Originate is the factory default.

The AT command for Disable is &L0.

The AT command for 2-wire Originate is &L1.

The AT command for 4-wire Originate is &L2.

The AT command for 2-wire Answer is &L3.

The AT command for 4-wire Answer is &L4.

3910-A2-GN32-30

November 1996

4-33

Page 136
Image 136
Paradyne 3910 operation manual Leased Line Configuration Options