COMSPHERE 3900 Series Modems

To change a factory template using AT commands, perform the following steps. For more information on changing factory templates using AT commands, refer to Chapter 5, AT Command Set and S-Registers.

1.Use the AT&F&W command to load the appropriate factory configuration to the appropriate storage area. Enter the following:

TYPE: AT&Fy&Wn

Where: y is one of the following Factory configurations:

0 for Async Dial

1 for Sync Dial

2 for Sync Leased (Answer)

3 for UNIX Dial

4 for Sync Leased (Originate)

5 for Async Leased (Answer)

6 for Async Leased (Originate)

7 for TMp (Control)

8 for TMp (Trib)

NOTE

Only &F0, &F3, &F5, and &F6 allow you to use AT commands after saving a factory configuration. Any other selection removes AT command control. The only way to return to AT command control is through the DCP as described earlier in Using the DCP.

Where: n is one of the following storage areas:

0 for Active (Saved)

1 for Customer 1

2 for Customer 2

NOTE

These three configuration areas are nonvolatile memory locations. Active (Saved) contains the most recently saved changes to any configuration options. In the event of power loss, the modem retrieves these configuration options. Customer 1 and Customer 2 are user-defined configuration areas.

PRESS: Return (Enter)

2. The selected factory configuration is saved.

To establish a connection with a remote modem, use the D (Dial) command. Refer to Chapter 5, AT Commands and S-Registers, for more on AT commands.

2-8

November 1996

3910-A2-GN32-30

Page 30
Image 30
Paradyne 3910 operation manual Type AT&Fy&Wn