AT Command Set and S-Registers

Table 5-3

(7 of 8)

391x Series AT Commands

AT

 

 

Description

 

DCP LCD

 

 

 

Command

Command

 

 

 

 

 

 

 

 

Sequence

 

 

 

 

 

 

 

 

 

 

 

 

\Dn

CTS Control.

 

 

 

Configure\Edit\

 

\D0

Forced On. Forces CTS to always ON.

 

DTE Interface

 

 

 

 

\D1

Standard RS232.

 

 

 

 

\D2

Wink When Disconnect. CTS is turned OFF for 1 to 2 seconds

 

 

 

upon a disconnect.

 

 

 

 

\D3

Follows DTR. The state of CTS follows the state of DTR.

 

 

\D4

Follows RTS. The state of CTS follows the state of RTS.

 

 

 

 

 

 

\Gn

Modem to Modem Flow Control.

 

 

Configure\Edit\

 

\G0

Disable.

 

 

 

V42/MNP/Buffer

 

 

 

 

 

 

\G1

Enable.

 

 

 

 

 

 

 

\Kn

Buffer Control, Send Break Control, Break Forces Escape.

Break Buffer

 

 

 

 

 

 

Control:

 

 

 

Break Buffer

Send Break

Break Forces

Configure\Edit\

 

 

 

V42/MNP/

 

 

 

Control:

Control:

Escape:

 

 

 

 

 

 

\K0

Discard Data

Break First

Enable

Send Break

 

 

Control:

 

 

\K1

Discard Data

Break First

Disable

 

 

Configure\Edit\

 

 

\K2

Keep Data

Break First

Enable

 

 

\K3

Keep Data

Break First

Disable

V42/MNP/Buffer

 

 

\K4

Keep Data

Data First

Enable

Break Forces

 

 

\K5

Keep Data

Data First

Disable

 

 

 

 

 

 

Escape:

 

 

 

 

 

 

Configure\Edit\

 

 

 

 

 

 

DTE Dialer

 

 

 

 

 

 

\Nn

Error Control Mode.

 

 

 

Configure\Edit\

 

\N0

Buffer Mode.

 

 

V42/MNP/Buffer

 

 

 

 

 

\N1

Direct Mode.

 

 

 

 

\N2

MNP or Disconnect.

 

 

 

 

\N3

MNP or Buffer.

 

 

 

 

\N4

V.42/MNP or Disconnect.

 

 

 

 

\N5

V.42/MNP or Buffer.

 

 

 

 

\N6

LAPM_or_Disc

 

 

 

 

\N7

LAPM_or_Bufr

 

 

 

 

 

 

 

\Qn

Flow Control of DTE, Flow Control of Modem.

 

Configure\Edit\

 

 

 

Flow Control

Flow Control

 

V42/MNP/Buffer

 

 

 

 

 

 

 

 

of DTE:

of Modem:

 

 

 

 

\Q0

Disable

Disable

 

 

 

 

\Q1

XON/XOFF

XON/XOFF

 

 

 

 

\Q2

CTS to DTE

Disable

 

 

 

 

\Q3

CTS to DTE

RTS to Mdm

 

 

 

 

\Q4

XON/XOFF

Disable

 

 

 

 

\Q5

Disable

XON/XOFF

 

 

 

 

\Q6

Disable

RTS to Mdm

 

 

 

 

 

 

 

 

 

3910-A2-GN32-30

November 1996

5-13

Page 167
Image 167