DCP Configuration
Table
(2 of 2)
Test Configuration Options
Test Timeout: Disable
Nxt Disable 30sec 60sec 240sec
Test
HDisable
Allows a test to run indefinitely.
H30, 60, or 240 seconds
Allows the test to run for 30 seconds, 60 seconds, or 240 seconds.
The AT command is
Rcv Remote Loop: Enable
Nxt Enable Disable
This configuration option is not available if the LeasedLine Rate is configured for TMp.
Receive Remote Loopback Response. Determines if the modem responds to a request for a remote loopback issued from a remote modem.
The AT command for Enable is &T4.
The AT command for Disable is &T5.
V54 Address: Disable
Nxt Disable (Address Values)
This configuration option is not available if the LeasedLine Rate is configured for TMp.
V.54 Address. Determines which remote 391x Series modem is placed into a remote loopback test. This test can be either a remote digital loopback or local analog loopback. This type of addressing is recommended for use in extended data circuits (tail circuits).
HDisable
This is used for normal
HAddress Values
01, 03, 05, 07, 09, 0B, 0D, 0F, 11, 13, 15, 17, 19, 1B, 1D, 1F, 25, 27, 2B, 2D, 2F, 33, 35, 37, 3B, 3D, 3F, 55, 57, 5B, 5F, 6F, 77, or 7F. This configuration option selects the address of a modem that is to be placed into a loopback test. This option is used for more complex networks where multiple modems, used in extended data circuits (tail circuits), can be commanded to loopback.
The AT command for Disable is
The AT command for V.54 Address is
V54 Device Type: Peripheral
End Peripheral Intermediate
This configuration option is only available if V54 Address is enabled and the LeasedLine Rate is configured for TMp.
V.54 Device Type. Identifies where the modem is physically located in the network.
HPeripheral
The modem is located at the endpoint of the network and is not connected
HIntermediate
The modem is either of the two modems connected
The AT command for Peripheral is
The AT command for Intermediate is
November 1996 |