COMSPHERE 3900 Series Modems

Manual Dialing When the Remote Modem is Configured for Manual Answer

NOTE

On both modems, the Line Current Disconnect configuration option (refer to the Line Dialer section in Chapter 4) must be set to Disable.

This configuration option does not appear on Models 3910-A1-401 and 3911-B1-001.

If you are originating a call using a telephone and the remote modem is configured for Manual Answer, perform the following procedure.

Once the remote telephone is answered by the remote user, you must both decide when to place the modems into Data mode. You must both select Tlk/Data at approximately the same time and hang up the handset to begin the handshaking sequence.

If the handshake is successful, the modems are in Data mode and OnLine appears on the LCD.

NOTE

If the remote modem is not a 3900 Series modem, then the remote user must consult that modem's operator's manual to perform a similar operation.

Once the modems are online, the status messages listed in Table 3-3 appear on the Top-Level display.

It is not necessary to specify an originating or answering modem when dialing via the DCP because the answering modem detects that it is receiving a ringing voltage and automatically defaults to Answer mode.

Security Branch

The Security branch allows you to create, edit, and save parameters that determine how the modem's security is executed. For security procedures and configuration options, refer to Chapter 6, Dial Access Security.

3-64

November 1996

3910-A2-GN32-30

Page 98
Image 98
Paradyne 3910 operation manual Security Branch