COMSPHERE 3900 Series Modems

Table 5-4

(6 of 13)

391x Series S-Registers

S-Register

Description

DCP LCD

Command

 

 

Sequence

 

 

 

S53

V.54 Address. Identifies the address of the modem to be placed in a

Configure\Edit\

 

loopback test.

Tests

 

Register has the following values:

 

 

0 = Disable

 

 

1±34 = Modem address

 

 

The factory setting is Disable.

 

 

 

 

S54

V.54 Device Type. Identifies where the modem is physically located in

Configure\Edit\

 

the network.

Tests

 

Register has the following values:

 

 

0 = Peripheral

 

 

1 = Intermediate

 

 

The factory setting is Peripheral.

 

 

 

 

S55

Access From Remote. Register determines if a modem's DCP can be

Configure\Edit\

 

accessed by a remote modem.

Misc

 

Register has the following values:

 

 

0 = Enable

 

 

1 = Disable

 

 

The factory setting is Enable.

 

 

 

 

S56

Remote Access Password. Register allows entry of the first pair

Configure\Edit\

 

(leftmost) of digits of a remote access password. Any value from 00 to

Misc

 

99 is valid. For example, if the remote access password is 12345678,

 

 

then S56 = 1 and 2.

 

 

 

 

S57

Remote Access Password. Register allows entry of the second pair of

Configure\Edit\

 

digits of a remote access password. Any value from 00 to 99 is valid.

Misc

 

 

 

S58

Remote Access Password. Register allows entry of the third pair of

Configure\Edit\

 

digits of a remote access password. Any value from 00 to 99 is valid.

Misc

 

 

 

S59

Remote Access Password. Register allows entry of the fourth pair

Configure\Edit\

 

(rightmost) of digits of a remote access password. Any value from 00

Misc

 

to 99 is valid.

 

 

 

 

5-20

November 1996

3910-A2-GN32-30

Page 174
Image 174
Paradyne 3910 operation manual Dcp Lcd