COMSPHERE 3900 Series Modems

 

Table B-2

 

Leased-Line Operation

 

 

Symptom

Action

 

 

The modems do not train-up on

Verify that the correct cabling is used for your application. Refer to

leased lines.

Chapter 2, Modem Installation.

 

Verify that one modem is configured for Answer mode and the other is

 

configured for Originate mode. (For TMp operation one modem must

 

be configured as a control modem and the other as a tributary

 

modem.)

 

Verify that both modems are using the same modulation scheme.

 

Verify that both modems are configured for the appropriate leased-line

 

mode. For example, if you have a 4-wire leased line, then the modems

 

must be configured for 4-wire operation.

 

 

 

Table B-3

 

Dial Backup Operation

 

 

Symptom

Action

 

 

The dial backup line is present,

Verify that the correct telephone number for the remote modem is

but the modems cannot connect.

stored in directory location 1.

 

Verify that both modems have the Auto Dial Backup configuration

 

option set to Enable. Refer to Leased Line in Chapter 4.

 

Call the answering modem with a handset and verify that the modem's

 

answer tone is transmitted.

 

 

The modem does not switch

Verify that the Auto Dial Standby configuration option is enabled. Refer

back to leased-line operation.

to Leased Line in Chapter 4.

 

 

B-2

November 1996

3910-A2-GN32-30

Page 187
Image 187
Paradyne 3910 Table B-2, Leased-Line Operation, Must be configured for 4-wire operation, Table B-3, Dial Backup Operation