9 • Maintaining and Updating

Cleaning or Replacing the Wick

continued

10.Place the shield and wick assembly in the moistener tank and push down on the shield to push the as- sembly into the tank.

11.Replace the moistener tank and gently slide it back into the machine, taking care not to crimp the supply tubing. Do not push the tank all the way back into the machine yet.

12. Replace the E-Z Seal® Seal- ing Solution bottle. Wait for about 5 minutes and then check to make sure the moistener tank is filled with the correct amount of E-Z Seal® solution. Measure the amount of solution as shown in the diagram on the right.

The solution level should be:

14 - 18 mm (0.55 - 0.71 in.)

Solution level

If, after 5 minutes, the moistener tank is not filled to the correct level, remove the E-Z Seal® bottle, wait 20 seconds and then replace it again.

If after another 5 minutes the level is still not correct, go to step 13. Otherwise go to step 14.

9-10

SV60890 Rev. G

Page 142
Image 142
Pitney Bowes DM550, DM500 manual 14 18 mm 0.55 0.71