Hold it in this position for ap- proximately 20 seconds.

DM500™and DM550™ Digital Mailing System Operating Guide

Cleaning or Replacing the Wick

continued

13.Remove the moistener tank and hold it as high as you can above the machine as shown in the picture on the right.

Hold it in this position for ap- proximately 20 seconds.

a.Replace the moistener tank again and gently slide it back into the machine, taking care not to crimp the supply tub- ing. Do not push the tank all the way back into the ma- chine yet.

b.Wait about 5 minutes and then check the level of E- Z Seal® Sealing Solution again as described in step 12 above.

c.If the tank is still not filled to the correct level, re- move the moistener tank and drain it over the front of the machine, then re- place the tank and check the level again after 5 minutes.

14.Once you verify that the moistener tank is filled to the correct level with E-Z Seal® Solution, gently push the tank all the way back to its original position.