4 – Managing Switches Displaying Switch Information

S

Table 4-2. Switch Data Window Entries (Continued)

Entry

Description

 

 

Security Fabric Binding

N/A - does not apply to this switch

Enable

 

Temperature

Internal switch temperature °C

Fan 1 Status

N/A - does not apply to this switch

Fan 2 Status

N/A - does not apply to this switch

Fan 3 Status

N/A - does not apply to this switch

Power Supply 1 Status

Power supply 1 status

Power Supply 2 Status

N/A - does not apply to this switch

Beacon Status

Beacon status. Switch LEDs are blinking (On) or not (off).

Broadcast Support

Broadcast support status. Broadcast support is enabled or

 

disabled (default).

In-band Enabled

In-band management status. Permits (True) or prevents

 

(False) a switch from being managed over an ISL.

Temperature Failure Port

Non-configurable (always enabled for this switch). All

Shutdown

ports are downed when the switch temperature exceeds

 

the Failure Temperature.

Warning Temperature

Non-configurable temperature threshold (65° Celsius)

 

above which a warning condition alarm is generated.

Failure Temperature

Non-configurable temperature threshold (70° Celsius)

 

above which a failure condition alarm is generated.

NTP Client Enabled

Enabled or disabled. Allows for switches to synchronize

 

their time a centralized server.

NTP Server Address

The IP address of the centralized NTP server. Ethernet

 

connection to NTP server is required.

FDMI Enabled

This field does not apply to this switch.

FDMI HBA Entry Limit

This field does not apply to this switch.

Number of Donor Groups

Total number of donor port groups. A donor group is a set

 

of ports on a switch that can donate buffer credits to each

 

other.

Embedded GUI Enabled

SANsurfer Switch Manager web applet status.

 

 

4-10

59226-00 B

Page 98
Image 98
Q-Logic 59226-00 B manual Switch Data Window Entries