Set Setup Command

 

 

 

 

snmp

Prompts you in a line-by-line fashion to change SNMP configuration settings. Table A-25describes the SNMP fields. For each parameter, enter a new value or press the Enter key to accept the current value shown in brackets.

 

Table A-25. SNMP Configuration Settings

 

 

 

Entry

 

Description

 

 

 

SNMPEnabled

 

Enables (True) or disables (False) SNMP on the switch. The

 

 

default is True.

Contact

 

Specifies the name of the person to be contacted to respond to

 

 

trap events. The name can be up to 64 characters excluding #,

 

 

semicolon (;), and comma (,). The default is undefined.

Location

 

Specifies the name of the switch location. The name can be up

 

 

to 64 characters excluding #, semicolon (;), and comma (,).

 

 

The default is undefined.

Trap [1-5] Address

 

Specifies the workstation IP address to which SNMP traps are

 

 

sent. The default address for trap 1 is 10.0.0.254. The default

 

 

address for traps 2–5 is 0.0.0.0. Addresses, other than 0.0.0.0,

 

 

for all traps must be unique.

Trap [1-5] Port

 

Specifies the workstation port to which SNMP traps are sent.

 

 

Valid workstation port numbers are 1–65535. The default is

 

 

162.

Trap [1-5] Severity

 

Specifies the severity level to use when monitoring trap events.

 

 

The default is Warning.

Trap [1-5] Version

 

Specifies the SNMP version (1 or 2) to use in formatting traps.

 

 

The default is 2.

Trap [1-5] Enabled

 

Specifies whether traps (event information) are enabled or

 

 

disabled (default).

ReadCommunity

 

Read community password that authorizes an SNMP agent to

 

 

read information from the switch. This is a write-only field. The

 

 

value on the switch and the SNMP management server must

 

 

be the same. The read community password can be up to 32

 

 

characters excluding #, semicolon (;), and comma (,). The

 

 

default is “public”.

WriteCommunity

 

Write community password that authorizes an SNMP agent to

 

 

write information to the switch. This is a write-only field. The

 

 

value on the switch and the SNMP management server must

 

 

be the same. The write community password can be up to 32

 

 

characters excluding #, semicolon (;), and comma (,). The

 

 

default is “private”.

 

 

 