0 | A – Command Line Interface |
| |
| Show Command |
|
|
|
|
Examples The following is an example of the Show Chassis command:
SANbox2 #> show | chassis |
|
Chassis Information |
| |
| ||
BoardTemp (1) | - Degrees Celsius | 32 |
BoardTemp (2) | - Degrees Celsius | 36 |
FanStatus (1) |
| Good |
FanStatus (2) |
| Good |
PowerSupplyStatus (1) | Good | |
PowerSupplyStatus (2) | Good | |
HeartBeatCode |
| 1 |
HeartBeatStatus | Normal |
The following is an example of the Show Domains command:
SANbox2 #> show domains |
| |
Principal switch | is (remote): 10:00:00:60:69:50:0b:6c | |
Upstream Principal ISL is | : 1 | |
Domain ID List: |
|
|
Domain 97 | (0x61) | WWN = 10:00:00:c0:dd:00:71:ed |
Domain 98 | (0x62) | WWN = 10:00:00:60:df:22:2e:0c |
Domain 99 | (0x63) | WWN = 10:00:00:c0:dd:00:72:45 |
Domain 100 | (0x64) | WWN = 10:00:00:c0:dd:00:ba:68 |
Domain 101 | (0x65) | WWN = 10:00:00:60:df:22:2e:06 |
Domain 102 | (0x66) | WWN = 10:00:00:c0:dd:00:90:ef |
Domain 103 | (0x67) | WWN = 10:00:00:60:69:50:0b:6c |
Domain 104 | (0x68) | WWN = 10:00:00:c0:dd:00:b8:b7 |
The following is an example of the Show Fabric command:
SANbox2 #> show fabric
Domain | WWN | Enet IP Addr | FC IP Addr | SymbolicName | |
16 | (0x10) | 10:00:00:c0:dd:00:77:81 | 10.20.68.11 | 0.0.0.0 | gui sb1 .11 |
17 | (0x11) | 10:00:00:c0:dd:00:6a:2d | 10.20.68.12 | 0.0.0.0 | sw12 |
18 | (0x12) | 10:00:00:c0:dd:00:c3:04 | 10.20.68.160 | 0.0.0.0 | sw .160 |
19 | (0x13) | 10:00:00:c0:dd:00:bc:56 | 10.20.68.108 | 0.0.0.0 | Sb2 .108 |