4 – Managing Switches

0

 

 

Displaying Switch Information

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 4-2. Switch Data Window Entries (Continued)

 

 

 

 

 

Entry

Description

 

 

 

 

 

 

Interop Mode

Zoning merge status. When a zone set is activated on an

 

 

 

 

FC-SW-2 compliant switch, only the active zone set is

 

 

 

 

propagated to all switches in the fabric. When a zone set

 

 

 

 

is activated on a non-FC-SW-2 compliant switch, the

 

 

 

 

active zone set and all inactive zone sets (the entire

 

 

 

 

zoning database) are stored in permanent memory. The

 

 

 

 

Interop Mode setting must be the same on all switches in

 

 

 

 

the fabric, otherwise the inter-switch links will not connect.

 

 

Legacy Address Format

Legacy port addressing status. Enabled only for

 

 

 

 

interoperability with non-FC-SW-2 compliant switches.

 

 

Interop Auto Save

Zoning auto save status. Saves zoning updates in

 

 

 

 

temporary memory and the zoning database (True) or

 

 

 

 

only in temporary memory (False).

 

 

Zoning Default Visibility

Zoning visibility status. Permits (All) or prevents (None)

 

 

 

 

communication between attached devices in the absence

 

 

 

 

of an active zone set.

 

 

Security Auto Save

N/A - does not apply to this switch

 

 

Security Fabric Binding

N/A - does not apply to this switch

 

 

Enable

 

 

 

Temperature

Internal switch temperature °C

 

 

Fan 1 Status

Fan 1 status

 

 

Fan 2 Status

Fan 2 status (SANbox2-16 only)

 

 

Fan 3 Status

Fan 3 status (SANbox2-64 only)

 

 

Power Supply 1 Status

Power supply 1 status

 

 

Power Supply 2 Status

Power supply 2 status (SANbox2-16 only)

 

 

Beacon Status

Beacon status. Switch LEDs are blinking (On) or not (off).

 

 

Broadcast Support

Broadcast support status. Broadcast support is enabled or

 

 

 

 

disabled (default).

 

 

In-band Enabled

In-band management status. Permits (True) or prevents

 

 

 

 

(False) a switch from being managed over an ISL.

 

 

Temperature Failure Port

Non-configurable (always enabled for this switch). All

 

 

Shutdown

ports are downed when the switch temperature exceeds

 

 

 

 

the Failure Temperature.

 

 

 

 

 

 

4-10

59022-11 A

Page 116
Image 116
Q-Logic SANBOX2-16, 59022-11 A 4-13 manual Switch Data Window Entries