A – Command Line Interface

 

 

Set Config Command

 

 

 

 

threshold

Initiates a configuration session by which to generate and log alarms for selected events. The system displays each event, its triggers, and sampling window one line at a time and prompts you for a value. For each parameter, enter a new value or press the Enter key to accept the current value shown in brackets. These parameters must be saved in a configuration and activated before they will take effect. Refer to the ”Config Command” on page A-16for information about saving and activating a configuration. Table A-21describes the Set Config Threshold parameters. The switch will down a port if an alarm condition is not cleared within three consecutive sampling windows (by default 30 seconds). Reset the port to bring it back online. An alarm is cleared when the threshold monitoring detects that the error rate has fallen below the falling trigger.

Table A-21. Set Config Threshold Parameters

Parameter

 

Description

 

 

Threshold Monitoring Enabled

Master enable/disable parameter for all

 

events. Enables (True) or disables (False)

 

the generation of all enabled event alarms.

 

The default is False.

CRCErrorsMonitoringEnabled

The event type enable/disable parameter.

DecodeErrorsMonitoringEnabled

Enables (True) or disables (False) the

ISLMonitoringEnabled

generation of alarms for each of the

LoginMonitoringEnabled

following events:

LogoutMonitoringEnabled

„

CRC errors

LOSMonitoringEnabled

„

Decode errors

 

„

ISL connection count

 

„

Device login errors

 

„

Device logout errors

 

„ Loss-of-signal errors

Rising Trigger

The event count above which a rising

 

trigger alarm is logged. The switch will not

 

generate another rising trigger alarm for

 

that event until the count descends below

 

the falling trigger and again exceeds the

 

rising trigger.

Falling Trigger

The event count below which a falling

 

trigger alarm is logged. The switch will not

 

generate another falling trigger alarm for

 

that event until the count exceeds the

 

rising trigger and descends again below

 

the falling trigger.

Sample Window

The period of time in seconds in which to

 

count events.

 

 

 

59022-11 A