0 | A – Command Line Interface |
| |
| Set Config Command |
|
|
|
|
threshold
Initiates a configuration session by which to generate and log alarms for selected events. The system displays each event, its triggers, and sampling window one line at a time and prompts you for a value. For each parameter, enter a new value or press the Enter key to accept the current value shown in brackets. These parameters must be saved in a configuration and activated before they will take effect. Refer to the ”Config Command” on page
Table A-21. Set Config Threshold Parameters
Parameter |
| Description |
|
| |
Threshold Monitoring Enabled | Master enable/disable parameter for all | |
| events. Enables (True) or disables (False) | |
| the generation of all enabled event alarms. | |
| The default is False. | |
CRCErrorsMonitoringEnabled | The event type enable/disable parameter. | |
DecodeErrorsMonitoringEnabled | Enables (True) or disables (False) the | |
ISLMonitoringEnabled | generation of alarms for each of the | |
LoginMonitoringEnabled | following events: | |
LogoutMonitoringEnabled | | CRC errors |
LOSMonitoringEnabled | | Decode errors |
| | ISL connection count |
| | Device login errors |
| | Device logout errors |
| | |
Rising Trigger | The event count above which a rising | |
| trigger alarm is logged. The switch will not | |
| generate another rising trigger alarm for | |
| that event until the count descends below | |
| the falling trigger and again exceeds the | |
| rising trigger. | |
Falling Trigger | The event count below which a falling | |
| trigger alarm is logged. The switch will not | |
| generate another falling trigger alarm for | |
| that event until the count exceeds the | |
| rising trigger and descends again below | |
| the falling trigger. | |
Sample Window | The period of time in seconds in which to | |
| count events. | |
|
|
|