Appendix A Connecting Peripheral Instruments
A-11
Connecting to Ockam Instruments
Navigator connects to Ockam instruments via Ockam’s Model 050D
RS-232 Interface (which you must supply). You must also set two
switches on the Ockam unit.
Note: You can connect Navigator to any model Ockam
RS-232 Interface; however, to ensure optimum
reliability of the data transfer, we recommend
that you use Ockam Model 050D.
To connect to an Ockam Model 050D RS-232 Interface:
1. Set Switch S1 on Model 050D to 4.
2. Set Switch S2 to D.
3. Refer to Figure A-1 and Table A-9 to make the required cable
connections.
Table A-9. Connecting Navigator to an Ockam 050D RS-232 Interface
Connect Cable Color: To Ockam 050D Pin:
Yellow (Rx) Pin 4
Blue (SGnd) Not used
Green (Tx) Pin 2
Black (SGnd) Pin 1