INSTRUCTION SETS3F80JB

INC — Increment

INC dst

Operation: dst dst + 1

The contents of the destination operand are incremented by one.

Flags:

C:

Unaffected.

 

Z:

Set if the result is "0"; cleared otherwise.

 

S:

Set if the result is negative; cleared otherwise.

 

V:

Set if arithmetic overflow occurred; cleared otherwise.

 

D:

Unaffected.

 

H:

Unaffected.

Format:

 

Bytes Cycles Opcode

Addr Mode

(Hex)

dst

dst opc

opc

dst

 

 

1

4

rE

r

 

 

r = 0 to F

 

2

4

20

R

 

4

21

IR

Examples: Given: R0 = 1BH, register 00H = 0CH, and register 1BH = 0FH:

INC

R0

R0

= 1CH

INC

00H

Register 00H = 0DH

INC

@R0

R0

= 1BH, register 01H = 10H

In the first example, if destination working register R0 contains the value 1BH, the statement "INC R0" leaves the value 1CH in that same register.

The next example shows the effect an INC instruction has on register 00H, assuming that it contains the value 0CH.

In the third example, INC is used in Indirect Register (IR) addressing mode to increment the value of register 1BH from 0FH to 10H.