DEVELOPMENT TOOLS DATAS3F80JB

Table 20-2. Default Setting of the Jumper in S3F80JB Target Board

JP#

Description

1-2 connection

 

2-3 connection

Setting

S1

Target board power source

Open-ice power

 

 

Join 1-2

JP1

Target board mode selection

H: Main-Mode

L: EVA-Mode

Join 2-3

JP2

Operation Mode

H: User Mode

L: Test-Mode

Join 1-2

JP3

MDS version

SMDS2

SMDS2+

Join 2-3

JP5

Board peripheral power

Board peripheral power connection

Connect

 

connection

 

 

 

 

JP6

When supplied 5V in target

In case of selection 3.3V

 

In case of selection 5V

Join 2-3

 

board, generation of 3.3V

between open-ice powers,

 

between open-ice powers,

 

 

using regulator.

connect core without a step

connect regulator to

 

 

 

of regulation.

 

generate 3.3V

 

JP8

80JB VDD power connection

80JB VDD power connection

 

Connect

JP10

Clock source selection

When using the internal clock source which is generated

 

 

 

from OPENice-i500, join connector 2-3 and 4-5 pin. If

 

 

 

user wants to use the external clock source like a crystal,

 

 

 

user should change the jumper setting from 1-2 to 5-6

 

 

 

and connect Y1 to an external clock source.

 

JP11

Regulator 3.3 Volt-Out

Connection between regulator out voltage and 80JB’s

 

 

connection

Power VDD when using the regulator. When debugging

 

 

 

with Openice-i500, JP11 don’t need to be connect.

 

SW2

Smart option at address 3EH

Dip switch for smart option. These 1byte are mapped

 

 

 

address 3EH for special function. Refer to the page 2-3.

 

SW3

Smart option at address 3FH

Dip switch for smart option. These 1byte are mapped

 

 

 

address 3FH for special function. Refer to the page 2-3.

 

Y1

External clock source

Connecting point for external clock source like a crystal.

 

J3

Header for flash serial

To program an internal flash, connect the signals with

J3

 

programming signals

flash writer tool.

 

 

 

To

Target System is supplied

Target Board is not supplied

Target Board is supplied

Join 2-3

User_Vcc

VDD

VDD to Target System.

 

VDD to Target System.

 

NOTE: S3F80JB Target board consists of 74HC11N, regulator and other components. In case of 74HC11N, typical operating voltage is 5V. So 80jb target board includes a regulator for 3.3V generation. As you know, S3F80JB typical operating voltage is 3.3V. Although open-i500 supports 3.3 V for target board ‘s power source, we recommend that you connect jumper of open-i500 power source to 5V. Check the interface board’s jumper status between emulator and target board.

nRESET LED

This LED is OFF when the Reset switch is ON.

IDLE LED

This is LED is ON when the evaluation chip (S3E80JB) is in idle mode.

STOP LED

This LED is ON when the evalution chip (S3E80JB) is in stop mode.

20-4

Page 333
Image 333