S3F80JB

 

 

FLAGS REGISTER (FLAGS)

The flags register FLAGS contains eight bits that describe the current status of CPU operations. Four of these bits, FLAGS.7–FLAGS.4, can be tested and used with conditional jump instructions; two others FLAGS.3 and FLAGS.2 are used for BCD arithmetic.

The FLAGS register also contains a bit to indicate the status of fast interrupt processing (FLAGS.1) and a bank address status bit (FLAGS.0) to indicate whether bank 0 or bank 1 is currently being addressed. FLAGS register can be set or reset by instructions as long as its outcome does not affect the flags, such as, Load instruction.

Logical and Arithmetic instructions such as, AND, OR, XOR, ADD, and SUB can affect the Flags register. For example, the AND instruction updates the Zero, Sign and Overflow flags based on the outcome of the AND instruction. If the AND instruction uses the Flags register as the destination, then simultaneously, two write will occur to the Flags register producing an unpredictable result.

System Flags Register (FLAGS)

D5H, Set 1, Bank0 , R/W

MSB

.7

.6

.5

.4

.3

.2

.1

.0

 

 

 

 

 

 

 

 

 

LSB

Carry flag (C)

Zero flag (Z)

Bank address status flag (BA)

First interrupt status flag (FIS)

Sign flag (S)

Half-carry flag (H)

Overflow (V)

Decimal adjust flag (D)

Figure 6-1. System Flags Register (FLAGS)