Samsung S3F80JB Dec Hex, Cadatal, Timer 1 Data Register High Byte, Timer 1 Data Register Low Byte

Models: S3F80JB

1 346
Download 346 pages 34.13 Kb
Page 234
Image 234

RESET

S3F80JB

 

 

Table 8-3. Set 1, Bank 0 Register Values After Reset (Continued)

Register Name

Mnemonic

Address

 

 

Bit Values After Reset

 

 

 

 

Dec

Hex

7

6

 

5

4

3

2

 

1

0

Port 1 Control Register (High Byte)

P1CONH

234

EAH

1

1

 

1

1

1

1

 

1

1

Port 1 Control Register (Low Byte)

P1CONL

235

EBH

0

0

 

0

0

0

0

 

0

0

Port 2 Control Register (High Byte)

P2CONH

236

ECH

0

0

 

0

0

0

0

 

0

0

Port 2 Control Register (Low Byte)

P2CONL

237

EDH

0

0

 

 

0

0

0

 

0

 

0

0

Port 2 Pull-up Enable Register

P2PUR

238

EEH

0

0

 

0

0

0

0

 

0

0

Port 3 Control Register

P3CON

239

EFH

0

0

 

0

0

0

0

 

0

0

Port 4 Control Register

P4CON

240

F0H

0

0

 

0

0

0

0

 

0

0

Port 0 Interrupt Enable Register

P0INT

241

F1H

0

0

 

0

0

0

0

 

0

0

Port 0 Interrupt Pending Register

P0PND

242

F2H

0

0

 

0

0

0

0

 

0

0

Counter A Control Register

CACON

243

F3H

0

0

 

0

0

0

0

 

0

0

Counter A Data Register (High Byte)

CADATAH

244

F4H

1

1

 

1

1

1

1

 

1

1

Counter A Data Register (Low Byte)

CADATAL

245

F5H

1

1

 

1

1

1

1

 

1

1

Timer 1 Counter Register (High Byte)

T1CNTH

246

F6H

0

0

 

0

0

0

0

 

0

0

Timer 1 Counter Register (Low Byte)

T1CNTL

247

F7H

0

0

 

0

0

0

0

 

0

0

Timer 1 Data Register (High Byte)

T1DATAH

248

F8H

1

1

 

1

1

1

1

 

1

1

Timer 1 Data Register (Low Byte)

T1DATAL

249

F9H

1

1

 

1

1

1

1

 

1

1

Timer 1 Control Register

T1CON

250

FAH

0

0

 

0

0

0

0

 

0

0

STOP Control Register

STOPCON

251

FBH

0

0

 

0

0

0

0

 

0

0

Locations FCH is not mapped. ( For factory test )

 

 

 

 

 

 

 

Basic Timer Counter

BTCNT

253

FDH

0

0

 

 

0

0

0

 

0

 

0

0

External Memory Timing Register

EMT

254

FEH

0

1

 

 

1

1

1

 

1

 

0

Interrupt Priority Register

IPR

255

FFH

x

x

 

 

x

x

x

 

x

 

x

x

NOTES:

1.Although the SYM register is not used, SYM.5 should always be “0”. If you accidentally write a 1 to this bit during normal operation, a system malfunction may occur.

2.Except for T0CNTH, T0CNTL, IRQ, T1CNTH, T1CNTL, T2CNTH, T2CNTL, and BTCNT, which are read-only, all registers in set 1 are read/write addressable.

3.You cannot use a read-only register as a destination field for the instructions OR, AND, LD, and LDB.

8-16

Page 234
Image 234
Samsung S3F80JB manual Dec Hex, Cadatal, Timer 1 Data Register High Byte, Timer 1 Data Register Low Byte