Schneider Electric HRB1684301-01 Custom alarms parameter list, Alarm parameter Unit

Models: HRB1684301-01

1 148
Download 148 pages 57.73 Kb
Page 93
Image 93

PowerLogic™ PM5500 series user manual

Chapter 10—Alarms

 

 

Custom alarms

Custom alarms (Cust1s) are setpoint-driven alarms, similar to the standard (1-Sec) alarms.

A custom alarm’s input parameters and setpoint subtypes can only be configured using software. The pickup setpoint and dropout setpoint limits are set to -999999 to 999999.

Custom alarms parameter list

Alarm parameter

Unit

 

 

Current A

A

 

 

Current B

A

 

 

Current C

A

 

 

Current N

A

 

 

Current G

A

 

 

Current Avg

A

 

 

Current Unbalance A

%

 

 

Current Unbalance B

%

 

 

Current Unbalance C

%

 

 

Current Unbalance Worst

%

 

 

Voltage A-B

V

 

 

Voltage B-C

V

 

 

Voltage C-A

V

 

 

Voltage L-L Avg

V

 

 

Voltage A-N

V

 

 

Voltage B-N

V

 

 

Voltage C-N

V

 

 

Voltage L-N Avg

V

 

 

Voltage Unbalance A-B

%

 

 

Voltage Unbalance B-C

%

 

 

Voltage Unbalance C-A

%

 

 

Voltage Unbalance L-L \Worst

%

 

 

Voltage Unbalance A-N

%

 

 

Voltage Unbalance B-N

%

 

 

Voltage Unbalance C-N

%

 

 

Voltage Unbalance L-N Worst

%

 

 

Active Power A

kW

 

 

Active Power B

kW

 

 

Active Power C

kW

 

 

Active Power Total

kW

 

 

Reactive Power A

kVAR

 

 

Reactive Power B

kVAR

 

 

Reactive Power C

kVAR

 

 

Reactive Power Total

kVAR

 

 

Apparent Power A

kVA

 

 

Apparent Power B

kVA

 

 

Apparent Power C

kVA

 

 

Apparent Power Total

kVA

 

 

Frequency

Hz

 

 

Temperature

°C

 

 

Alarm parameter

Unit

 

 

Active Energy Delivered

kW

 

 

Active Energy Received

kW

 

 

Active Energy Delivered + Received

kW

 

 

Active Energy Delivered - Received

kW

 

 

Reactive Energy Delivered

kVAR

 

 

Reactive Energy Received

kVAR

 

 

Reactive Energy Delivered + Received

kVAR

 

 

Reactive Energy Delivered - Received

kVAR

 

 

Apparent Energy Delivered

kVA

 

 

Apparent Energy Received

kVA

 

 

Apparent Energy Delivered + Received

kVA

 

 

Apparent Energy Delivered - Received

kVA

 

 

Input Metering CH 01 Accumulation

 

 

Input Metering CH02 Accumulation

 

 

Input Metering CH03 Accumulation

 

 

Input Metering CH04 Accumulation

 

 

Active Power Last Demand

kW

 

 

Active Power Present Demand

kW

 

 

Active Power Predicted Demand

kW

 

 

Reactive Power Last Demand

kVAR

 

 

Reactive Power Present Demand

kVAR

 

 

Reactive Power Predicted Demand

kVAR

 

 

Apparent Power Last Demand

kVA

 

 

Apparent Power Present Demand

kVA

 

 

Apparent Power Predicted Demand

kVA

 

 

Current A Last Demand

A

 

 

Current A Present Demand

A

 

 

Current A Predicted Demand

A

 

 

THD Current A

%

 

 

THD Current B

%

 

 

THD Current C

%

 

 

THD Current N

%

 

 

THD Current G

%

 

 

thd Current A

%

 

 

thd Current B

%

 

 

thd Current C

%

 

 

thd Current N

%

 

 

thd Current G

%

 

 

Min Freq

Hz

 

 

Max Active Power A

kW

 

 

Max Total Demand Distortion

%

 

 

Max Freq

%

 

 

HRB1684301-01

93

Page 93
Image 93
Schneider Electric HRB1684301-01 user manual Custom alarms parameter list, Alarm parameter Unit