16.216.2 Specifications for the STP Control Unit

STP-H600/H1000 Series Instruction Manual

16.216.2 Specifications for the STP Control Unit

Table 16.2 Specifications for the STP Control Unit

 

Item

 

 

Specifications

 

Input voltage

V AC

 

200 to 240±10%

Input power

At start:

kVA

 

2.6

 

Under rated operation:

kVA

 

1.0 to 2.6

 

 

 

 

Input frequency

Hz

 

50/60±2

 

Input phase

 

 

Single phase

 

Rated current of main breaker

A

 

20

 

Motor drive system

 

 

3-phase transistor-inverter

Output voltage under rated

V AC

 

52

 

operation(3-phase)

 

 

 

 

 

 

 

Output frequency under rated

Hz

 

584

 

operation

 

 

 

 

 

 

 

Ambient temperature range

 

0 to 40

 

Storage temperature range

 

- 25 to + 55 (excluding a battery)

Battery storage temperature range

 

- 20 to + 40

 

Mass*1

kg

 

40

 

Battery used

 

12 V 2Ah x 4 (Japan Storage Battery Co.,

 

 

 

Ltd./Small-Sized Sealed Lead-Acid

 

 

 

Battery/PORTALAC series PE12V2WS)

Operation switches

 

[Front Panel]

 

 

 

 

￿￿

POWER ON/OFF

 

 

 

 

 

(Illuminated alternate push button

 

 

 

 

switch, black/green)

 

 

 

 

￿￿

MOTOR START

 

 

 

 

 

(Momentary push button switch, black)

 

 

 

￿￿

MOTOR STOP

 

 

 

 

 

(Momentary push button switch, red)

 

 

 

￿￿

HEATING ON/OFF

 

 

 

 

 

(Illuminated alternate push button

 

 

 

 

switch, black/green)

 

 

 

 

[Rear Panel]

 

 

 

 

￿￿

MANUAL/REMOTE Changeover

 

 

 

 

(Toggle switch)

 

Panel indication lamps

 

￿￿

ACCELERATION

(Green LED)

 

 

 

￿￿

NORMAL OPERATION

(Green LED)

 

 

 

￿￿

BRAKE

(Yellow LED)

 

 

 

￿￿ EMERGENCY OPERATION (Red LED)

 

 

 

￿￿

FAILURE

(Red LED)

 

 

 

￿￿

OVER TEMPERATURE

(Red LED)

 

 

 

￿￿

BATTERY OPERATION

(Red LED)

 

 

 

￿

 

 

 

 

 

￿￿

[Switch built-in Lamps]

 

 

 

 

￿￿ POWER ON (POWER ON/OFF, green)

 

 

 

￿￿ HEATING ON (HEATING ON/OFF,

 

 

 

 

green)

 

*1 : Mass is a value of state that the only standard accessory was installed. (except the optional accessory)

16-2

Page 114
Image 114
Seiko Instruments MT-17E-003-D instruction manual Specifications for the STP Control Unit