10 External Battery

STP-H600/H1000 Series Instruction Manual

10 External Battery

Manual backgroundManual background CAUTION Manual background

DO NOT use (an) external batteries when internal batteries are inserted. Failure to do so may result in product damage or a problem.

It could cause a problem, such as product damage.

DO NOT connect batteries in parallel.

Replace batteries with new ones before the end of their life.

When the STP pump is left unused over the specified period, charge battery for 90 minutes, or replace it with a new one before starting the STP pump.

Manual backgroundNOTICEManual backgroundManual backgroundManual background

The life, allowable shelf life, and operation frequency of the battery differ depending upon the type of the battery and ambient temperatures. See technical data and information prepared by the battery manufacturer.

10.1Specifications for the External Battery

When you use external batteries, select one in accordance with the specifications given in Table 10.1.

Manual backgroundManual background CAUTION Manual background

If you use external batteries which do not conform to the specifications, battery backup will not function during a power failure which could result in damage to the STP pump.

Table 10.1 Specifications for the External Battery

Item

Specifications

 

 

Capacity

1.8 Ah or more

 

 

Voltage

48 V

 

 

Current

2.3 A

 

 

Operation time

Approx. 6 minutes

 

 

Operation frequency

Continues 2 times or more

 

 

Charging voltage

55 V

 

 

It is recommended to use PORTALAC Series Small-Size Sealed Lead-Acid Battery manufactured by Japan Storage Battery Co., Ltd. as an external battery.