Item |
| Specifications |
Input/output terminal | AC POWER TB1 (3 pins) | |
| P.CONNECTOR CON5A (45 pins) | |
| INVERTER OUTPUT CON2A (5 pins) | |
| LEAK VALVE CON8A (8 pins) | |
| I/O TB2 (20 pins) | |
| DC I/O TB3 (10 pins) | |
| START STOP TB5 (3 pins) | |
| START/STOP TB6 (2 pins) | |
| EXT. BATTERY CON9 (2 pins) | |
Input/output cables | Primary power cable | |
| STP connection cable | |
| Motor connection cable | |
| Emergency vent. valve cable | |
| Ground cable | |
Safety functions | Magnetic bearing abnormality/error | |
|
| detection |
|
| (Rotor vibration: 100μm |
| STP pump overheat detection | |
|
| (Motor: 110 ℃ over) |
| Inverter overload detection | |
|
| (Inverter current: 40 A over, |
|
| instantaneous, A over for 15 minutes) |
| Battery abnormality/error detection | |
|
| (Battery terminal voltage: 42 V under) |
| Power failure detection | |
|
| (Detects power failure of over about 2 |
|
| seconds) |
| STP pump overspeed detection | |
|
| (37500 rpm over) |
| STP control unit overheat detection | |
|
| (90℃ over) |
| Brake failure detection |