STP-H600/H1000 Series Instruction Manual

Item

 

Specifications

Input/output terminal

￿￿

AC POWER TB1 (3 pins)

 

￿￿ P.CONNECTOR CON5A (45 pins)

 

￿￿ INVERTER OUTPUT CON2A (5 pins)

 

￿￿ LEAK VALVE CON8A (8 pins)

 

￿￿ I/O TB2 (20 pins)

 

￿￿ DC I/O TB3 (10 pins)

 

￿￿ START STOP TB5 (3 pins)

 

￿￿ START/STOP TB6 (2 pins)

 

￿￿ EXT. BATTERY CON9 (2 pins)

Input/output cables

￿￿

Primary power cable

 

￿￿

STP connection cable

 

￿￿

Motor connection cable

 

￿￿ Emergency vent. valve cable

 

￿￿

Ground cable

Safety functions

￿￿

Magnetic bearing abnormality/error

 

 

detection

 

 

(Rotor vibration: 100μm p-p or more)

 

￿￿ STP pump overheat detection

 

 

(Motor: 110 over)

 

￿￿

Inverter overload detection

 

 

(Inverter current: 40 A over,

 

 

instantaneous, A over for 15 minutes)

 

￿￿

Battery abnormality/error detection

 

 

(Battery terminal voltage: 42 V under)

 

￿￿

Power failure detection

 

 

(Detects power failure of over about 2

 

 

seconds)

 

￿￿ STP pump overspeed detection

 

 

(37500 rpm over)

 

￿￿ STP control unit overheat detection

 

 

(90over)

 

￿￿

Brake failure detection

16-3