Table 8.2 shows rated contacts for relays CR1 to 4, CR7, and CR10 (See Figure 8.1) and CR8 (See Figure 8.4).
Table 8.2 Rated Contacts for Relays CR1 to 4, CR7, CR8 and CR10
| Resistance Load | Induction Load | |||||
| (cos φ=0.4) | ||||||
| (cos φ=1) | ||||||
| (L/R=7 ms) | ||||||
|
|
|
| ||||
Rated Load | 250 V AC | 10 A | 250 V AC | 5A | |||
30 V DC | 10 A | 30 V DC | 5A | ||||
| |||||||
Rated Current |
|
| 10 A |
|
| ||
Maximum Contact Point |
|
| 380 V AC |
|
| ||
Voltage |
|
| 125 V DC |
|
| ||
Maximum Contact Point |
|
| 10 A |
|
| ||
Current |
|
|
|
| |||
|
|
|
|
|
| ||
Maximum Open/Close | AC: | 2500 VA | AC: | 1250 VA | |||
Capacity | DC: | 300 W | DC: | 220 W | |||
Minimum |
|
| 5 V DC | 10 mA |
|
| |
Applicable Load |
|
|
|
| |||
|
|
|
|
|
|
Table 8.3 shows rated contacts for relays CR5 and 6 (see Figure 8.1).
Table 8.3 Rated Contacts for Relays CR5 and 6
| Resistance Load |
| Induction Load | |||
|
| (cos φ=0.4) | ||||
| (cos φ=1) |
| ||||
|
| (L/R=7 ms) | ||||
|
|
|
|
| ||
Rated Load | 250 V AC | 10 A |
| 250 V AC | 7.5 A | |
30 V DC | 10 A |
| 30 V DC | 5A | ||
|
| |||||
Rated Current |
|
| 10 A |
| ||
Maximum Contact Point |
|
| 380 V AC |
| ||
Voltage |
|
| 125 V DC |
| ||
Maximum Contact Point |
|
| 10 A |
| ||
Current |
|
|
| |||
|
|
|
|
|
| |
Maximum Open/Close | AC: | 2500 VA |
| AC: 1875 VA | ||
Capacity | DC: | 300 W |
| DC: 150 W | ||
Minimum |
|
| 5 V DC | 100 mA |
| |
Applicable Load |
|
|
| |||
|
|
|
|
|
|