Siemens 6AU1900-1AB32-0BA0 configurationmanual Cyclic relative execution type, you can select

Models: 6AU1900-1AB32-0BA0

1 86
Download 86 pages 2.68 Kb
Page 33
Image 33

 

 

 

Configuring

 

 

 

3.5 Customize the display of the cam

 

 

 

 

 

 

Field/button

Explanation/instructions

 

Representation range

 

 

 

Start

Specify here the Start point of the representation range.

 

 

(Number of periods deactivated)

If the Number of periods option has been activated, the

 

 

 

system will determine the start point.

 

 

End

Specify here the End point of the representation range.

 

 

(Number of periods deactivated)

If the Number of periods option has been activated, the

 

 

 

system will determine the end point.

 

 

Number of periods

If under Target device parameters in the Coordinates tab,

 

 

(cyclical absolute,

you have specified the cyclic absolute execution type or the

 

 

cyclical relative)

cyclic relative execution type, you can select the

 

 

 

option Number of periods. Enter the number of periods that

 

 

 

you want to display.

 

Grid lines

 

 

 

Set automatically

If you activate Set automatically, the grid lines will be

 

 

 

displayed automatically with an optimum spacing.

 

 

 

If you deactivate Set automatically, you can use Main line

 

 

 

spacing or Auxiliary line spacing to specify the grid line

 

 

 

spacing.

 

 

Main line spacing

You can activate the display of the grid lines for the main

 

 

 

line spacing here.

 

 

 

If you deactivate the Set automatically option, you can

 

 

 

specify the grid line spacing for the main line spacing.

 

 

 

Note:

 

 

 

The spacing that you specify for the grid lines in the main

 

 

 

line spacing must be a multiple of the spacing that you

 

 

 

specify for the grid lines in the auxiliary line spacing.

 

 

Auxiliary line spacing

If the main line spacing option has been activated, you can

 

 

(Main line spacing activated)

also activate the display of the grid lines for the auxiliary line

 

 

 

spacing.

 

 

 

If you deactivate the Set automatically option, you can

 

 

 

specify the grid line spacing for the auxiliary line spacing.

 

 

 

Note:

 

 

 

The spacing that you specify for the grid lines in the main

 

 

 

line spacing must be a multiple of the spacing that you

 

 

 

specify for the grid lines in the auxiliary line spacing.

CamTool

3-19

Configuration Manual, 12.2004, 6AU1900-1AB32-0BA0

Page 33
Image 33
Siemens 6AU1900-1AB32-0BA0 configurationmanual Cyclic relative execution type, you can select