Functions

4.8 Optimizing a Cam

Parameters

You can specify the parameters of the interpolation curve for the transition here.

You can set the following parameters:

Table 4-2

Parameters in the Parameters tab (Interpolation Curve Properties window)

 

 

 

 

 

 

Field/button

Explanation/instructions

Jerk at boundary point

 

(allow interpolation by target device

 

deactivated)

 

 

(for 6th degree polynomial)

 

 

Automatically

If you activate Automatically, the jerk value at the boundary points is

 

 

 

calculated by the system. A polynomial of the 5th degree is used for the

 

 

 

calculation.

 

 

 

Note:

 

 

 

You can activate this function via the context menu in the diagram

 

 

 

representation: Right-click the transition and select Automatic jerk

 

 

 

characteristic in the context menu.

 

Left

 

If you activate Left, you can specify the jerk at the left boundary point of

 

(automatically deactivated)

the interpolation curve. Enter the jerk value in the input field.

 

Right

 

If you activate Right, you can specify the jerk at the right boundary point

 

(automatically deactivated)

of the interpolation curve. Enter the jerk value in the input field.

 

(Jerk value)

If you activate the option Left or the option Right, you can enter the jerk

 

(automatically deactivated)

value here.

 

 

 

Note:

 

 

 

To specify an absolute jerk value, you must select an absolute master

 

 

 

velocity for calculations in the Simulation Settings window.

Curve point of inflexion

 

(allow interpolation by target device

 

deactivated)

 

 

(for inclined sine curve)

 

(for modified sine curve)

 

(for modified acceleration trapezoid)

 

(for harmonic combination)

 

 

Valid values are between 0 and 1

You can enter the turning point of the curve here.

 

Optimum value

If you click this button, the optimum value for the turning point of the

 

 

 

curve is calculated by the system and entered under Valid values are

 

 

 

between 0 and 1.

 

 

 

Note:

 

 

 

You can activate this function via the context menu in the diagram

 

 

 

representation: Right-click the transition and select Optimum value in the

 

 

 

context menu.