Siemens 6AU1900-1AB32-0BA0 configurationmanual Change sine curve definition range

Models: 6AU1900-1AB32-0BA0

1 86
Download 86 pages 2.68 Kb
Page 56
Image 56

Functions

4.5 Sine curve

2.Enter the new position in the Position tab and click OK. The sine curve is shown at the new position.

Figure 4-9 Position (Fx Sine Properties) tab

4.5.3Change sine curve definition range

Requirements

The cam is opened with SIMOTION CamTool.

Change sine curve definition range

To change the definition range of a sine curve:

1.Select the sine curve in the S diagram (distance diagram). The current position of the sine curve is shown in the tooltip.

2.The sine curve is shown with handles. The handles for the definition range are shown in green. Point to a green handle. The mouse pointer shows the direction in which you can move the handle.

3.Move the green handles with drag&drop to the new positions. While moving, the current value of the respective limit of the definition range is displayed in the tooltip.

Figure 4-10 Change sine curve definition range

4-14

CamTool

Configuration Manual, 12.2004, 6AU1900-1AB32-0BA0

Page 56
Image 56
Siemens 6AU1900-1AB32-0BA0 configurationmanual Change sine curve definition range