CHAPTER 4 Backup Server Error Messages
711
3.48.1 1 The Backup Server will go down immediately.
Terminating sessions.
Explanation: This is the final message sent to the
session that issued the shutdown command.
3.49.2 2 RPC %1! does not allow option %2!.
Explanation: An RPC inconsistency was detected.
This could be caused by incompatible releases of
Backup Server and Adaptive Server.
3.50.2 2 Non-privileged connection is not authorized to exec ute
privileged RPC `%1!'.
Explanation: Some RPCs are “privileged,” that is,
they can only occur in the context of an Adaptive
Server-initiated dump. Users who attempt to
programmatically duplicate one of these RPCs are
prevented from doing so.
3.51.2 2 Database device #%1!, name %2! has already been
declared as #%3!, name %4!.
Explanation: Internal error, contact Sybase
Technical Support. The dump or load command as
translated by Adaptive Server does not make sense.
The sysdevices table may be corrupt.
3.52.2 2 Database device #%1! has not been declared.
Explanation: Internal error, contact Sybase
Technical Support. The dump or load command as
translated by Adaptive Server does not make sense.
The sysdevices table may be corrupt.
3.53.2 2 Malformed option list received, RPC: %1!.
Explanation: Internal error, contact Sybase
Technical Support. The dump or load options as
passed from Adaptive Server do not make sense. The
problem may be possible to work around by
rearranging, adding or removing options to the dump
or load command.
3.54.1 1 Waiting for processes to complete.
Explanation: This message is sent to the session
issuing a shutdown command if there are outstanding
dump or load requests and nowait was not specified.
3.55.2 2 RPC %1!, parameter `%2!': `%3!' is an invalid value.
Explanation: Internal error, contact Sybase
Technical Support. Adaptive Server requested an
unknown function.
Number Severity Text and Explanation