CHAPTER 6 Adaptive Server Error Messages
769
246 16 The conversion of CHAR value `%.*s' overflowed an INT2 field, use a larger integer
field.
Explanation: Command failed due to invalid or illegal request. Check syntax,
semantics, and permissions. Take any corrective action indicated by message.
247 16 Arithmetic overflow during %S_MSG conversion of %s value `%s' to a %s field .
Explanation: Refer to the writeup for Error 247.
248 16 The conversion of CHAR value `%.*s' overflowed an INT4 field. Maximum intege r
value exceeded.
Explanation: Adaptive Server could not perform the requested action. Modify your
command to meet the Adaptive Server requirement for the objects or variables shown in
the error message.
249 16 Syntax error during %S_MSG conversion of %s value `%s' to a %s field.
Explanation: Command failed due to invalid or illegal request. Check syntax,
semantics, and permissions. Take any corrective action indicated by message.
251 16 Unable to allocate ancillary table for query optimization. Maximum number of tables in
a query (%d) exceeded.
Explanation: Adaptive Server could not perform the requested action. Rewrite the
command to conform to the requirement specified in the error message.
252 16 Can't group by a bit field.
Explanation: Adaptive Server could not perform the requested action. Modify your
command to meet the Adaptive Server requirement for the objects or variables shown in
the error message.
253 16 Maximum number of group-by expressions exceeded. Limit is %d, found %d aggregate
expressions.
Explanation: Adaptive Server could not perform the requested action. Modify your
command to meet the Adaptive Server requirement for the objects or variables shown in
the error message.
254 16 Maximum number of columns in a work table (%d) exceeded.
Explanation: Adaptive Server could not perform the requested action. Modify your
command to meet the Adaptive Server requirement for the objects or variables shown in
the error message.
255 16 Size of row in the worktable for grouped aggregate, %d bytes, exceeds the maximu m row
size (%d bytes). Cannot run this query.
Explanation: Adaptive Server could not perform the requested action. Rewrite the
command to conform to the requirement specified in the error message.
256 16 The data type `%s' is invalid for the %s function. Allowed types are: CHAR/VARCHAR
and BINARY/VARBINARY.
Explanation: Command failed due to invalid or illegal request. Check syntax,
semantics, and permissions. Take any corrective action indicated by message.
Number Severity Text and Explanation