4-8

MDM-1 AES/EBU Digital I/O Module

Power

Symbol

Description

Minimum

Typical

Maximum

Units

VA18P

Pos Analog Supply Voltage

17.50

18.00

20.00

Volts

VA18M

Neg Analog Supply Voltage

 

Not Used

 

Volts

VD5P

Pos Digital Supply Voltage

4.75

5.00

5.50

Volts

IA18P

Pos Analog Supply Current

8

9

10

mA

IA18M

Neg Analog Supply Current

 

Not Used

 

mA

ID5P

Pos Digital Supply Current

122

155

168

mA

Performance

(Sample Rate Converter Engaged)1

Symbol

Description

Minimum

Typical

Maximum

Units

F

Sample Rate for Digital

32

48

>54

kHz

sInput Data2

THD+N

Total Harmonic Distortion

 

0.00002

0.00016

%

 

plus Noise3 (RELATIVE)

 

 

 

 

 

IMD

Intermodulation Distortion4

 

 

 

TBD

%

 

(SMPTE 4:1)

 

 

 

 

 

 

Jitter in Output Clock5

 

 

 

415

pS

 

(700 Hz - 100KhZ)

 

 

 

 

 

 

Tolerable Jitter in Input

 

 

 

90

nS

 

Clock before Loss of Lock6

 

 

 

 

 

 

Resolution (input)7

4

 

 

20

bits

 

Resolution (output)8

24

24

24

bits

 

Frequency Response9

 

 

 

+/-0.01

dB

 

Dynamic Range10

 

117

120

dB

 

Noise Floor11

 

-117

 

dBFS

 

Delay through transmitter12

 

43/

64

 

WST+

 

 

 

 

 

periods

 

Interchannel Phase Deviation13

 

 

 

 

 

 

0

 

 

Degrees

MCLK/2

Sample Rate Converter

 

 

 

 

 

 

Reference Clock Source14

4.333

6.144

6.667

MHz

MCLK+

Master Clock

TBD

12.288

TBD

MHz

WSR+

Receive Word Clock15

 

(MCLK+)/256

 

Hz

WST+

Transmit Word Clock16

 

(MCLK+)/256

 

Hz

SCKR+

Receive Bit Clock17

 

(MCLK+)/4

 

Hz

SCKT+

Transmit Bit Clock18

 

(MCLK+)/4

 

Hz

10 July 1998

Page 40
Image 40
Telex ISP-100 manual MDM-1 AES/EBU Digital I/O Module, Performance Sample Rate Converter Engaged1